Foxboro PH10-1N2Q |
|
|
|
Description
|
Model
|
PH10
|
=
|
Provides Highly Accurate And
Stable pH Measurements In Process Applications. NOTE: Mounting Hardware
Accessories Have Longer Lead Times Than The Base Sensor. If 1 Week Delivery Is
Required For The Sensor, Order the Mounting Hardware Accessories As Separate
Line Items.
|
PH10
|
|
pH ELECTRODE TYPE:
|
|
|||
1
|
=
|
Domed Glass High Temperature Bulb
With Protective Guard
|
1
|
|
2
|
=
|
Domed Glass High Temperature Bulb
Without Protective Guard
|
2
|
|
3
|
=
|
Flat Ruggedized Glass
|
3
|
|
4
|
=
|
Antimony
|
4
|
|
ELECTRONIC CONFIGURATION:
|
|
|||
N
|
=
|
None
|
N
|
|
P
|
=
|
Internal Preamp
|
P
|
|
S
|
=
|
Smart
|
S
|
|
TEMPERATURE COMPENSATION:
|
|
|||
1
|
=
|
2-Wire, 100 ohm Platinum RTD
|
1
|
|
2
|
=
|
3-Wire, 1000 ohm Platinum RTD
|
2
|
|
3
|
=
|
2-Wire, 100 ohm Platinum RTD,
Enhanced Response Speed
|
3
|
|
4
|
=
|
3-Wire, 1000 ohm Platinum RTD,
Enhanced Response Speed
|
4
|
|
5
|
=
|
2-Wire, 3 kohm Balco RTD
|
5
|
|
SENSOR TERMINATION:
|
|
|||
A
|
=
|
10 Ft (3.05 m) Integral Cable
Terminated w/Crimped -On Straight Pin Lugs
|
A
|
|
B
|
=
|
10 Ft (3.05 m) Integral Cable
Terminated w/Variopin "Quick" Connector
|
B
(b)
|
|
Q
|
=
|
Variopin "Quick"
Connector Integral To Sensor
|
Q
(c)
|
|
S
|
=
|
Smart Connector Integral To Sensor
|
S
(c)
|
|
OPTIONAL MODEL SUFFIX(ES)
INCLUDED:
|
|
|||
E
|
=
|
EPDM O-Ring
|
E
(d)
|
|
C
|
=
|
Chemraz O-Ring
|
C
(d)
|
|
2
|
=
|
Integral Sensor Cable, 20 Ft (6.1
m) Long
|
2
|
|
3
|
=
|
Integral Sensor Cable, 30 Ft (9.1
m) Long
|
3
|
|
4
|
=
|
Integral Sensor Cable, 40 Ft (12.2
m) Long
|
4
|
|
5
|
=
|
Integral Sensor Cable, 50 Ft (15.2
m) Long
|
5
|
|
1H
|
=
|
Integral Hi-Temp Sensor Cable, 10
Ft (3.05 m) Long
|
1H
|
|
2H
|
=
|
Integral Hi-Temp Sensor Cable, 20
Ft (6.1 m) Long
|
2H
|
|
3H
|
=
|
Integral Hi-Temp Sensor Cable, 30
Ft (9.1 m) Long
|
3H
|
|
4H
|
=
|
Integral Hi-Temp Sensor Cable, 40
Ft (12.2 m) Long
|
4H
|
|
5H
|
=
|
Integral Hi-Temp Sensor Cable, 50
Ft (15.2 m) Long
|
5H
|
|
AA
|
=
|
ATEX, II 1 G Ex ia IIc,
Intrinsically safe, Zone 0
|
AA
|
|
AN
|
=
|
ATEX, II 3 G Ex icic IIC Energy
Limited, Zone 2
|
AN
|
|
CA
|
=
|
CSA and FMc, Ex ia IIC, Energy
Limited, Zone 0
|
CA
|
|
CN
|
=
|
CSA and FMc, Ex ic IIC,
Nonincendive, Cl I, II, III, Div 2, Zone 2
|
CN
|
|
FA
|
=
|
FM, Aex ia IIC, Intrinsically
safe, Class I, II, III, Div 1, Zone 0
|
FA
|
|
FN
|
=
|
FM, Aex ic IIC, Nonincendive,
Class I, II, III, Div 2, Zone 2
|
FN
|
|
DA
|
=
|
IECEx, II 1 G, Ex ia IIC,
Intrinsically safe, Zone 0
|
DA
|
|
DN
|
=
|
IECEx, II 3 G, Ex ic IIC, Energy
Limited, Zone 2
|
DN
|
|
(b) Requires mating patch cord with integral Variopin
connector, if not customer supplied. Not compatible with Ball Valve Assembly
mountings.
|
||||
(c) Requires mating patch cord with integral Variopin
connector, if not customer supplied.
|
||||
(d) Standard O-Ring material is Viton.
|
Vui lòng liên hệ với đại lý ủy quyền của Foxboro tại Việt Nam để được hỗ trợ: Foxboro Vietnam>>
Đăng nhận xét Blogger Facebook